Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022 ; 2022.
Article in English | Scopus | ID: covidwho-2322331

ABSTRACT

This investigation presents results of Computational Fluid Dynamics (CFD) modelling of aerosol behaviour within an arbitrary 'realistic' 100m2 office environment, with dynamic and variable respiratory droplet release profile applied based on published findings (Morawska et al., 2009). A multitude of ventilation strategies and configurations have been applied to the base model to compare the effectiveness of reducing the concentration of suspended aerosols over time. A key finding of the investigation indicates a relatively low sensitivity to increasing outside air percentage, and that the benefit from this strategy is heavily dependent on the in-duct droplet decay factor. The application of local recirculating air filtration systems with MERV-13 filters mounted on occupant desks proved significantly more effectiveness than increasing outside air concentration from 25% to 100% in reducing the quantity of suspended aerosols. This highlights that the ventilation industry should perhaps focus on opportunities to integrate filtration systems into furniture, partitions, cabinetry etc., and that an appliance-based solution may be more beneficial for reducing COVID-19 transmission in buildings (and likely more straightforward) than modifications to central ventilation systems, particularly in the application of refurbishments and retrofits. © 2022 17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022. All rights reserved.

2.
17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022 ; 2022.
Article in English | Scopus | ID: covidwho-2325446

ABSTRACT

This study investigates the effectiveness of an upper-room UVGI system in a small classroom. Mixing ventilation can increase virus removal when combined with a UVGI system more effectively than displacement ventilation combined with a UVGI system, especially in cases where the ventilation rate is low. © 2022 17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022. All rights reserved.

3.
Environ Sci Pollut Res Int ; 30(12): 33206-33228, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2289596

ABSTRACT

This paper presents the numerical results of particle propagation in open space, taking into account the temperature of the human body and the surface of the ground. And also, the settling of particles or droplets under the action of gravitational force and transport in the open air is taken into account, taking into account the temperature during the process of breathing and sneezing or coughing. The temperature of the body and the surface of the ground, different rates of particle emission from the mouth, such as breathing and coughing or sneezing, are numerically investigated. The effect of temperature, cross-inlet wind, and the velocity of particle ejection from a person's mouth on social distancing is being investigated using a numerical calculation. The variable temperature of the human body forms a thermal plume, which affects the increase in the trajectory of the particle propagation, taking into account the lateral air flow. The thermal plume affects the particles in the breathing zone and spreads the particles over long distances in the direction of the airflow. The result of this work shows that in open space, taking into account the temperature of the body and the surface of the ground, a 2-m social distance may be insufficient for the process of sneezing and social distance must be observed depending on the breathing mode.


Subject(s)
Human Body , Wind , Humans , Temperature , Particle Size , Physical Distancing , Respiratory Aerosols and Droplets , Sneezing
4.
28th IEEE International Conference on Engineering, Technology and Innovation, ICE/ITMC 2022 and 31st International Association for Management of Technology, IAMOT 2022 Joint Conference ; 2022.
Article in English | Scopus | ID: covidwho-2285889

ABSTRACT

The paper contributes to existing research on transmission of infectious diseases in indoor environments, with a focus on the SARS-Co V -2 virus, considered in an environment with a potentially high infectious risk, i.e. a university building. A multi-functional zone with variable occupancy schedules involving both students and staff is used as a case study. A computational fluid dynamics (CFD) model is developed to simulate and analyze three scenarios involving mixed, mechanical, and natural ventilation. Based on the physical and operational configuration of the selected zone, initial results show that mechanical ventilation involves areas of stagnant air (i.e. air velocity is less than 0.1m/s), while reliance on natural ventilation leads to increase in C02 levels. Hence, a mixed mode (natural and mechanical) ventilation is suggested. Then, based on the probability of the presence of (an) infected individual(s), considering the local COVID-19 incidence rate, initial estimates suggest that the Delta variant requires the air change rate (ACH) to be increased more than 1000 times, when compared to the original strain. The paper thus establishes a correlation between the prevalence of a given SARS-Co V -2 variant with the required air change rate, emphasizing the need to factor in not only the presence of infected individual(s), based on the local incidence rate, but also the viral charge of the dominant SARS-Co V -2 variant. The paper argues the need for a better controlled and optimized ventilation to ensure safer indoor environments. © 2022 IEEE.

5.
European Journal of Mechanics, B/Fluids ; 97:93-110, 2023.
Article in English | Scopus | ID: covidwho-2241661

ABSTRACT

The Covid-19 global pandemic has reshaped the requirements of healthcare sectors worldwide. Following the exposure risks associated with Covid-19, this paper aims to design, optimise, and validate a wearable medical device that reduces the risk of transmission of contagious droplets from infected patients in a hospital setting. This study specifically focuses on those receiving high-flow nasal oxygen therapy. The design process consisted of optimising the geometry of the visor to ensure that the maximum possible percentage of harmful droplets exhaled by the patient can be successfully captured by a vacuum tube attached to the visor. This has been completed by deriving a number of concept designs and assessing their effectiveness, based on numerical analysis, computational fluid dynamics (CFD) simulations and experimental testing. The CFD results are validated using various experimental methods such as Schlieren imaging, particle measurement testing and laser sheet visualisation. Droplet capturing efficiency of the visor was measured through CFD and validated through experimental particle measurement testing. The results presented a 5% deviation between CFD and experimental results. Also, the modifications based on the validated CFD results improved the visor effectiveness by 47% and 38% for breathing and coughing events, respectively © 2022 The Author(s)

6.
Building and Environment ; 230, 2023.
Article in English | Scopus | ID: covidwho-2232441

ABSTRACT

With the increasing requirements for fresh air supply in buildings after the COVID-19 pandemic and the rising energy demand from buildings, there has been an increased emphasis on passive cooling techniques such as natural ventilation. While natural ventilation devices such as windcatchers can be a sustainable and low-cost solution to remove indoor pollutants and improve indoor air quality, it is not as reliable as mechanical systems. Integration with low-energy cooling, heating or heat recovery technologies is necessary for operation in unfavourable outdoor conditions. In this research, a novel dual-channel windcatcher design consisting of a rotary wind scoop and a chimney was proposed to provide a fresh air supply irrespective of the wind direction. The dual-channel design allows for passive cooling, dehumidification and heat recovery technology integration to enhance its thermal performance. In this design, the positions of the supply and return duct are "fixed” or would not change under changing wind directions. An open wind tunnel and test room were employed to experimentally evaluate the ventilation performance of the proposed windcatcher prototype. A Computational Fluid Dynamic (CFD) model was developed and validated to further evaluate the system's ventilation performance. The results confirmed that the system could supply sufficient fresh air and exhaust stale air under changing wind directions. The ventilation rate of the rotary scoop windcatcher was higher than that of a conventional 8-sided multidirectional windcatcher of the same size. © 2023 The Author(s)

7.
Int J Refrig ; 145: 78-89, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2076200

ABSTRACT

The outbreak of the COVID-19 has affected all aspects of people's lives around the world. As air transmits the viruses, air-conditioning systems in buildings, surrounded environments, and public transport have a significant role in restricting the transmission of airborne pathogens. In this paper, a computational fluid dynamic (CFD) model is deployed to simulate the dispersion of the COVID-19 virus due to the coughing of a patient in a conference hall, and the effect of displacement of supply and return registers of the air conditioning system is investigated. A validated Eulerian-Lagrangian CFD model is used to simulate the airflow in the conference hall. The particles created by coughing are droplets of the patient's saliva that contain the virus. Three cases with different positions of supply and return registers have been compared. The simulation results show that case1 has the best performance; since after 80 s in case 1 that the inlet registers are in the longitudinal wall, the whole particles are removed from space. However, in other cases, some particles are still in space.

8.
Aerosol and Air Quality Research ; 22(3), 2022.
Article in English | Scopus | ID: covidwho-1744783

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a highly infectious disease that emerged in December of 2019, threatening human health and leading to global public health crises. Airborne transmission via droplets and aerosol has been recently recognized as one of the infection modes for the SARS-CoV-2 virus. Hospitals have deployed/incorporated indoor air purifiers with the hope to minimize the transmission risk of SARS-CoV-2 virus. Nevertheless, the effectiveness of the indoor air purifier in reducing the transmission risk remained unknown. This study uses computational fluid dynamics to model the dispersion of the aerosol particles exhaled from the patient under the influence of an air conditioner, exhaust fans and air purifier. The numerical model showed that airflow from the diffusers, exhaust fans and placement of the air purifier significantly influenced the dispersion pattern of the aerosol particles in the common ward. Multiple air purifiers placed at 1 meter above the floor and next to a patient can increase the total efficiency from 37.14 to 59.91% for weak exhalation and from 36.44% to 48.81% for medium exhalation. No aerosol particles flew out from the door for weak and medium exhalation when multiple air purifiers were deployed in the common ward. Location and matching the clean air delivery rate with the size of the room are the important factors that affect the performance of the air purifier. © The Author(s).

9.
Int J Refrig ; 133: 313-325, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1549838

ABSTRACT

Most COVID-19 vaccines require ambient temperature control for transportation and storage. Both Pfizer and Moderna vaccines are based on mRNA and lipid nanoparticles requiring low temperature storage. The Pfizer vaccine requires ultra-low temperature storage (between -80 °C and -60 °C), while the Moderna vaccine requires -30 °C storage. Pfizer has designed a reusable package for transportation and storage that can keep the vaccine at the target temperature for 10 days. However, the last stage of distribution is quite challenging, especially for rural or suburban areas, where local towns, pharmacy chains and hospitals may not have the infrastructure required to store the vaccine. Also, the need for a large amount of ultra-low temperature refrigeration equipment in a short time period creates tremendous pressure on the equipment suppliers. In addition, there is limited data available to address ancillary challenges of the distribution framework for both transportation and storage stages. As such, there is a need for a quick, effective, secure, and safe solution to mitigate the challenges faced by vaccine distribution logistics. The study proposes an effective, secure, and safe ultra-low temperature refrigeration solution to resolve the vaccine distribution last mile challenge. The approach is to utilize commercially available products, such as refrigeration container units, and retrofit them to meet the vaccine storage temperature requirement. Both experimental and simulation studies are conducted to evaluate the technical merits of this solution with the ability to control temperature at -30 °C or -70 °C as part of the last mile supply chain for vaccine candidates.

10.
Environ Sci Pollut Res Int ; 28(38): 53478-53492, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1242814

ABSTRACT

The COVID-19 pandemic has plunged the world into uncharted territory, leaving people feeling helpless in the face of an invisible threat of unknown duration that could adversely impact the national economic growths. According to the World Health Organization (WHO), the SARS-CoV-2 spreads primarily through droplets of saliva or discharge from the mouth or nose when an infected person coughs or sneezes. However, the transmission of the SARS-CoV-2 through aerosols remains unclear. In this study, computational fluid dynamic (CFD) is used to complement the investigation of the SARS-CoV-2 transmission through aerosol. The Lagrangian particle tracking method was used to analyze the dispersion of the exhaled particles from a SARS-CoV-2-positive patient under different exhale activities and different flow rates of chilled (cooling) air supply. Air sampling of the SARS-CoV-2 patient ward was conducted for 48-h measurement intervals to collect the indoor air sample for particulate with diameter less than 2.5 µm. Then, the reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) was conducted to analyze the collected air sample. The simulation demonstrated that the aerosol transmission of the SARS-CoV-2 virus in an enclosed room (such as a hospital ward) is highly possible.


Subject(s)
COVID-19 , SARS-CoV-2 , Aerosols , Hospitals , Humans , Pandemics
11.
Sci Total Environ ; 773: 145537, 2021 Jun 15.
Article in English | MEDLINE | ID: covidwho-1061972

ABSTRACT

Virus-laden droplets dispersion may induce transmissions of respiratory infectious diseases. Existing research mainly focuses on indoor droplet dispersion, but the mechanism of its dispersion and exposure in outdoor environment is unclear. By conducting CFD simulations, this paper investigates the evaporation and transport of solid-liquid droplets in an open outdoor environment. Droplet initial sizes (dp = 10 µm, 50 µm, 100 µm), background relative humidity (RH = 35%, 95%), background wind speed (Uref = 3 m/s, 0.2 m/s) and social distances between two people (D = 0.5 m, 1 m, 1.5 m, 3 m, 5 m) are investigated. Results show that thermal body plume is destroyed when the background wind speed is 3 m/s (Froude number Fr ~ 10). The inhalation fraction (IF) of susceptible person decreases exponentially when the social distance (D) increases from 0.5 m to 5 m. The exponential decay rate of inhalation fraction (b) ranges between 0.93 and 1.06 (IF=IF0e-b(D-0.5)) determined by the droplet initial diameter and relative humidity. Under weak background wind (Uref = 0.2 m/s, Fr ~ 0.01), the upward thermal body plume significantly influences droplet dispersion, which is similar with that in indoor space. Droplets in the initial sizes of 10 µm and 50 µm disperse upwards while most of 100 µm droplets fall down to the ground due to larger gravity force. Interestingly, the deposition fraction on susceptible person is ten times higher at Uref = 3 m/s than that at Uref = 0.2 m/s. Thus, a high outdoor wind speed does not necessarily lead to a smaller exposure risk if the susceptible person locating at the downwind region of the infected person, and people in outdoors are suggested to not only keep distance of greater than 1.5 m from each other but also stand with considerable angles from the prevailing wind direction.


Subject(s)
Communicable Diseases , Exhalation , Humans
12.
J Hazard Mater ; 397: 122609, 2020 10 05.
Article in English | MEDLINE | ID: covidwho-45880

ABSTRACT

Droplet dispersion carrying viruses/bacteria in enclosed/crowded buses may induce transmissions of respiratory infectious diseases, but the influencing mechanisms have been rarely investigated. By conducting high-resolution CFD simulations, this paper investigates the evaporation and transport of solid-liquid mixed droplets (initial diameter 10 µm and 50 µm, solid to liquid ratio is 1:9) exhaled in a coach bus with 14 thermal manikins. Five air-conditioning supply directions and ambient relative humidity (RH = 35 % and 95 %) are considered. Results show that ventilation effectiveness, RH and initial droplet size significantly influence droplet transmissions in coach bus. 50 µm droplets tend to evaporate completely within 1.8 s and 7 s as RH = 35 % and 95 % respectively, while 0.2 s or less for 10 µm droplets. Thus 10 µm droplets diffuse farther with wider range than 50 µm droplets which tend to deposit more on surfaces. Droplet dispersion pattern differs due to various interactions of gravity, ventilation flows and the upward thermal body plume. The fractions of droplets suspended in air, deposited on wall surfaces are quantified. This study implies high RH, backward supply direction and passengers sitting at nonadjacent seats can effectively reduce infection risk of droplet transmission in buses. Besides taking masks, regular cleaning is also recommended since 85 %-100 % of droplets deposit on object surfaces.


Subject(s)
Exhalation , Ventilation , Motor Vehicles
SELECTION OF CITATIONS
SEARCH DETAIL